| Input data |
Lo= |
0.76 |
uH |
Inductance |
|
|
|
|
| |
Iopkx= |
97.7 |
Apk |
Inductor maximum peak current |
|
|
|
|
| |
Ioppx= |
15.3 |
App |
Max peak to peak current |
|
|
|
|
| |
Iodcx= |
90.0 |
Arms |
Max avg current |
|
|
|
|
| |
Ioacx= |
4.4 |
Arms |
Max AC rms ripple current |
|
|
|
|
| |
fdc= |
360 |
kHz |
Frequency for B variation |
|
|
|
|
| |
Icd= |
6.0 |
A/mm2 |
Current density |
|
|
|
|
| |
Smp= |
1.3 |
mm |
Safety margin, Pri/HF winding, mm |
|
|
|
|
| |
Sms= |
1.3 |
mm |
Safety margin, Sec/LF winding, mm |
|
|
|
|
| |
Whm= |
7.1 |
mm |
Min winding height, mm |
E42/21/15 |
|
|
|
| |
Wwm= |
25.5 |
mm |
Min winding width, mm |
E42/21/15 |
|
|
|
| |
Ht= |
15.4 |
mm |
Core height or "C" dimension |
E42/21/15 |
|
|
|
| |
Ltm= |
66.5 |
mm |
Min turn length |
E42/21/15 |
|
|
|
| |
le= |
98.4 |
mm |
Magnetic path length |
E42/21/15 |
|
|
|
| |
Ae= |
183 |
mm2 |
Magnetic core area, effective |
E42/21/15 |
|
|
|
| |
Am= |
183 |
mm2 |
Magnetic core area, minimum |
E42/21/15 |
|
|
|
| |
Vm= |
18,000 |
mm3 |
Magnetic volume |
E42/21/15 |
|
|
|
| |
ur= |
40 |
|
u, ungapped core, no DC bias |
K40 |
|
|
|
| |
Bmax= |
1.00 |
T |
Maximum flux density |
K40 |
|
|
|
| |
uh= |
90.5 |
% |
Permeability @ Hpk |
K40 |
|
|
|
| |
ncoin= |
1 |
|
Number of core sets |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Intermediate |
Ltm= |
66.5 |
mm |
Min turn length, ncoin sets |
|
|
|
|
| data |
Ltn= |
94.9 |
mm |
Average turn length, ncoin sets |
|
|
|
|
| |
Aet= |
183 |
mm2 |
Magnetic core area, effective, ncoin
sets |
|
|
|
|
| |
Amt= |
183 |
mm2 |
Magnetic core area, minimum, ncoin
sets |
|
|
|
|
| |
Vmt= |
18,000 |
mm3 |
Magnetic volume, ncoin sets |
|
|
|
|
| |
Vc= |
15,021 |
mm3 |
Copper volume |
|
|
|
|
| |
Vt= |
33,021 |
mm3 |
Total inductor volume |
|
|
|
|
| |
ALc= |
7.9 |
nH/T2 |
AL, coil only |
|
|
|
|
| |
ALo= |
93 |
nH/T2 |
AL, ungapped core, no DC bias, one set |
|
|
|
|
| |
ALot= |
93 |
nH/T2 |
AL, ungapped core, no DC bias, ncoin
sets |
|
|
|
|
| |
AL= |
85 |
nH/T2 |
AL, ungapped core, bias @ Hpk, ncoin
sets |
|
|
|
|
| |
ALg= |
84.7 |
nH/T2 |
Required core AL, gapped, bias @ Hpk |
|
|
|
|
| |
L0= |
0.07 |
uH |
Inductance, no cores |
|
|
|
|
| |
Lo0= |
0.91 |
uH |
Zero bias inductance, no gap, test
value |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Output data |
Nbmin= |
0.4 |
|
Minimum Number of turns |
|
|
|
|
| |
Nb= |
3.0 |
|
Number of turns, chosen |
> 1.2 x Nbmin |
|
|
|
| |
Bpk= |
0.14 |
T |
Actual peak flux density |
OK |
|
|
|
| |
Gap0= |
0.00 |
mm |
Core gap, no fringe effect |
|
|
|
|
| |
Gap= |
0.00 |
mm |
Core gap, closer to real |
|
|
|
|
| |
dBpk= |
11 |
mT |
Half of max B peak to peak variation |
|
|
|
|
| |
Hpksi= |
2,744 |
A/m |
Magnetizing Force, SI |
|
|
|
|
| |
Hpku= |
34 |
Oe |
Magnetizing Force, USA |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Output Inductor Core Loss |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Intermediate |
P3= |
2 |
mW/cm3 |
Philips Ferrite 3F3 material |
|
|
|
|
| data |
Pml= |
9 |
mW/cm3 |
Allied Signal MicroLite 245 material |
|
|
|
|
| |
Pm60= |
16 |
mW/cm3 |
Magnetics MPP 60u material |
|
|
|
|
| |
Pm125= |
26 |
mW/cm3 |
Magnetics MPP 125u material |
|
|
|
|
| |
Pk= |
61 |
mW/cm3 |
Magnetics Kool-Mu material |
|
|
|
|
| |
Ppl= |
117 |
mW/cm3 |
Allied Signal PowerLite material |
|
|
|
|
| |
Phf= |
41 |
mW/cm3 |
Magnetics High Flux 60u material |
|
|
|
|
| |
P18= |
117 |
mW/cm3 |
Micrometals Iron Powder 18 material |
|
|
|
|
| |
Rthm= |
8.9 |
°C/W |
Rth, toroid, open wound, natural
convection |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Output data |
P3= |
0.0 |
W |
3F3 |
|
|
|
|
| |
Pml= |
0.2 |
W |
MicroLite 245 |
|
|
|
|
| |
Pm60= |
0.3 |
W |
MPP 60u |
|
|
|
|
| |
Pm125= |
0.5 |
W |
MPP 125u |
|
|
|
|
| |
Pk= |
1.1 |
W |
Kool-Mu |
|
|
|
|
| |
Ppl= |
2.1 |
W |
PowerLite |
|
|
|
|
| |
Phf= |
0.7 |
W |
High Flux 60u |
|
|
|
|
| |
P18= |
2.1 |
W |
Iron Powder 18 |
|
|
|
|
| |
dT3= |
0 |
°C |
Core Temperature Rise, 3F3 |
|
|
|
|
| |
dTml= |
1 |
°C |
Core Temperature Rise, MicroLite 245 |
|
|
|
|
| |
dTm60= |
3 |
°C |
Core Temperature Rise, MPP 60u |
|
|
|
|
| |
dTm125= |
4 |
°C |
Core Temperature Rise, MPP 125u |
|
|
|
|
| |
dTk= |
10 |
°C |
Core Temperature Rise, Kool-Mu |
|
|
|
|
| |
dTpl= |
19 |
°C |
Core Temperature Rise, PowerLite |
|
|
|
|
| |
dThf= |
7 |
°C |
Core Temperature Rise, High Flux 60 |
|
|
|
|
| |
dT18= |
19 |
°C |
Core Temperature Rise, Iron Powder 18 |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Output Inductor Copper Loss |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Intermediate |
Dpenm= |
0.133 |
mm |
Penetration depth, mm |
|
|
|
|
| data |
Dpen= |
5.2 |
mil |
Penetration depth, mil |
|
|
|
|
| |
Sml= |
52 |
mil |
Safety margin, LF winding, mil |
|
|
|
|
| |
Smh= |
52 |
mil |
Safety margin, HF winding, mil |
|
|
|
|
| |
Ww= |
1.004 |
inch |
Winding width, available |
|
|
|
|
| |
Ltl= |
3.736 |
inch |
Average turn length, LF winding |
|
|
|
|
| |
Lth= |
3.736 |
inch |
Average turn length, HF winding |
|
|
|
|
| |
Wal= |
0.900 |
inch |
Winding width, LF winding |
|
|
|
|
| |
Waf= |
0.900 |
inch |
Winding width, HF winding |
|
|
|
|
| |
Dlf1= |
25.8 |
mil |
Thickness LF winding,required by
current density |
|
|
|
|
| |
Dlfc= |
60.0 |
mil |
Thickness, LF, chosen |
|
|
|
|
| |
Dlf2= |
90.2 |
mil |
Thickness, LF winding (winding height
limited) |
|
|
|
|
| |
Alf= |
34.84 |
mm2 |
Cross section area, LF winding |
|
|
|
|
| |
Dhf= |
7.620 |
mm |
Diameter, HF winding wire |
x 1 |
|
|
|
| |
Dhfc= |
1.524 |
mm |
Diameter, HF winding wire, chosen |
|
|
|
|
| |
Ahfc= |
34.84 |
mm2 |
Cross section area, HF winding, chosen |
|
|
|
|
| |
Qs= |
11.49 |
|
Layer thickness/penetration depth, HF
winding |
|
|
|
|
| |
Po= |
3.0 |
|
Number of layers per winding portion |
|
|
|
|
| |
Fro= |
72.79 |
|
Rac/Rdc ratio, HF winding |
|
|
|
|
| |
Tc= |
125.0 |
°C |
Actual copper temperature |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Output data |
Poicrl= |
1.1 |
W |
Core Power Loss, Kool-Mu |
|
|
|
|
| |
Pgap= |
0.0 |
W |
Gap related loss |
|
|
|
|
| |
Rdclf= |
0.2 |
mOhm |
DC resistance, low frequency winding |
|
|
|
|
| |
Rdchf= |
0.2 |
mOhm |
DC resistance, high frequency winding |
|
|
|
|
| |
Rachf= |
14.9 |
mOhm |
AC resistance, high frequency winding |
|
|
|
|
| |
Poilfl= |
1.7 |
W |
Low frequency winding copper loss |
|
|
|
|
| |
Poihfl= |
0.3 |
W |
High frequency winding copper loss |
|
|
|
|
| |
Poitcpl= |
1.9 |
W |
Total Copper Loss |
|
|
|
|
| |
Poitl= |
3.0 |
W |
Inductor total loss |
|
|
|
|
| |
Rth= |
6.4 |
°C/W |
Rth, toroid, open wound, natural
convection |
|
|
|
|
| |
dT3= |
19 |
°C |
Temperature Rise, natural convection |
For comparison only |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| We suggest using class H(180°C) for Power Magnetics (Boost
Inductor, Power Transformer and Output Inductor). |
|
|
|
| |
|
|
|
|
|
|
|
|
| The operating core temperature is assumed to be 100°C for core
loss calculation. |
|
|
|
|
| Minimum loss would be at 80-90°C. |
|
|
|
|
|
|
| Maximum core operating temperature should be <160°C
(Tc=200°C-40°C margin). |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| The accuracy of the formulas for core loss is expected to be
±10%. |
|
|
|
|
| The accuracy of the formulas for temperature rise is expected
to be ±30%. |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Temperature rise is for natural convection cooling. |
|
|
|
|
| For forced (fan) cooling the temperature rise could be 1/2 to
1/3, depending on airflow. |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| SMPS Power Supplies, Inc. |
|
|
|
|
|
|
| Doing The Right Thing Is The Right Thing To Doä |
|
|
|
|
|
| www.PowerSupplies.net |
|
|
|
|
|
|
| www.GoToPower.net |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Copyright © 1998-2005 SMPS Power Supplies,
Inc. All rights reserved. |
|
|
|
|
| Copyright © 1990-1997 LCD Consulting |
|
|
|
|
|
| Copyright © 1979-1989 Constantin Darius Livescu |
|
|
|
|